Deye C&I ESS Solution, 100kW-2.5MW, Three Phase, 8/10 MPPT

Price range: $858.00 through $10,320.00

ex GST
View Cart

Add the product to your cart and request a quote at checkout

 
SKU: Categories: Commercial Battery and InverterBrand: Deye
Dispatch in 48 Hours
On Products In Stock
Australian Company
Owned & Operated
10+ Years
Industry Experience
Lowest Price Guarantee
Beat By 3%

Description

The DEYE High Voltage C&I BOS-B Pro-A3 system is a modular commercial and industrial energy storage solution combining dedicated PCS, MPPT and STS modules with the BOS-B Pro-A3 battery system. The supplied range includes SUN-STS500L, SUN-MPPT-L01-EU-AM8, SUN-100K-PCS01HP3 and SUN-125K-PCS01HP3. Deye presents this architecture as a 100kW–2.5MW C&I ESS solution, with the PCS featuring integrated EMS and flexible integration with MPPT and STS modules.

Each module has a defined role. The PCS performs three-phase AC-to-DC rectification and DC-to-AC inversion. The MPPT module is a DC-DC converter designed to optimise matching between PV arrays and the battery or PCS input voltage. The STS manages grid-connected and off-grid operation and facilitates connections between generators, critical loads and grid interfaces.

The BOS-B Pro-A3 battery system uses 16.08kWh battery modules with 51.2V nominal voltage and 314Ah capacity. Between 5 and 16 battery modules can be connected in series, with a maximum system energy of 257.23kWh, maximum usable energy of 231.51kWh and maximum charge/discharge current of 180A.

Key Features of Product

  • Modular C&I architecture: The Deye C&I ESS solution combines battery, PCS, MPPT and STS functions in a configurable system architecture.
  • 100kW and 125kW PCS options: The two supplied PCS models provide 100kW and 125kW rated AC input/output active power respectively.
  • 500kW grid AC / STS module: The STS module provides 500kW rated AC input/output active power on the grid/PCS side, 500kW rated output power on the load side and 500kW rated AC input power on the generator side.
  • Fast transfer: SUN-STS500L provides less than 10ms on-grid/off-grid switching.
  • Eight-tracker PV integration: SUN-MPPT-L01-EU-AM8 provides eight MPP trackers, up to 200kW maximum PV access power and 160kW maximum PV input power.
  • High MPPT efficiency: The MPPT module has maximum efficiency above 99% and MPPT efficiency above 99.9%.
  • Integrated energy management: The PCS supports zero-export and time-of-use functions. The Deye C&I ESS solution also supports peak shaving and demand management.
  • High PCS efficiency: The listed PCS models have maximum efficiency of 98.5% and Euro efficiency of 97.8%.
  • Flexible communication: PCS interfaces include Wi-Fi, RS485, CAN and meter connections, while the MPPT module uses CAN/RS485.
  • Scalable architecture: One STS module can connect to five 100kW PCS modules or four 125kW PCS modules, with up to five STS modules in parallel.

Main Benefits

For commercial and industrial sites, the modular architecture allows the system to be configured around the required combination of battery storage, PV conversion and power transfer functions.

For backup applications, the STS module provides dedicated grid, load and generator paths and supports less than 10ms on-grid/off-grid switching.

For solar and storage integration, the MPPT module provides eight MPP trackers, up to 200kW of PV access power and a 630–1000V DC output range.

For energy management, the PCS includes zero-export and time-of-use control functions, while the system supports peak shaving and demand management.

For larger installations, the Deye C&I ESS solution can be expanded using multiple PCS and STS modules, with up to five STS modules in parallel.

Installation

Installation should be carried out only by qualified professionals or trained personnel. The manual requires the equipment to be powered off during installation and specifies appropriate protective equipment and insulated tools.

1. Prepare the installation area

Select a sheltered location with a solid foundation capable of supporting the module weight. The manual advises protecting the equipment from direct sunlight, rain, snow and lightning, while maintaining good airflow. Avoid explosive, corrosive, dusty, salty or high-interference environments.

2. Prepare and inspect the modules

Prepare the recommended installation tools and use suitable transport methods according to module weight. The supplied datasheet lists the PCS at 81.86kg, MPPT at 41.75kg and STS at 108kg. Move the units using the handles rather than the terminals.

3. Install the mounting brackets

For a combined PCS+MPPT+STS installation, construct the mounting frame and use the designated guide slots. Place the PCS and MPPT modules into their respective guide slots and secure the side mounting ears with screws. Open the installed cabinet door, place the STS into its guide slot and secure it with screws. The communication cable between the STS and PCS should not exceed 10m.

4. Connect the battery to the PCS

A separate DC over-current protector or disconnect device is required between the battery and PCS unless the battery has a readily accessible internal DC breaker. Connect the battery power cables to the PCS BAT terminals according to the polarity markings. Then connect the PCS BATBMS port to the corresponding battery control box interface using the supplied communication cable.

5. Connect the AC side and STS

When the STS is installed, it includes a built-in 250A AC breaker for the PCS AC cable and an auxiliary AC connection for the PCS. Follow the manual’s wiring sequence, connect the L1, L2 and L3 conductors to the STS AC breaker and connect the neutral conductor to the STS N-bar. Then connect the STS CAN port to the idle parallel port of the master PCS.

6. Connect the MPPT module

If the SUN-MPPT-L01-EU-AM8 is installed, disconnect the AC power source before wiring. Check PV string open-circuit voltage and polarity before connection. The manual recommends a PV junction box with surge protection and a DC circuit breaker between the PV strings and MPPT module. Connect the MPPT DC output to the PCS MPPT input, then connect the MPPT CAN port to the PCS MPPT_CAN port.

7. Complete grounding and commissioning

Connect the PCS grounding point to the Earth Bar. If MPPT and STS modules are installed, connect their grounding points to the same Earth Bar. Before operation, check cable connections, grounding, breakers and system settings. In a parallel system, all connected PCS units must be the same model, and each PCS should have its own separate battery set.

Deye

Deye is a Chinese high-tech enterprise and a subsidiary of the Deye Group. According to Deye’s Australian website, Ningbo Deye Inverter Technology Co., Ltd. was founded in 2007 with registered capital of CNY 400 million and a manufacturing plant covering more than 15,000m². The company focuses on integrated solar PV and energy storage solutions for residential, commercial and industrial applications.

Deye’s Australian site identifies 100/125kW–2.5MW C&I ESS solutions among its energy solutions. By the end of 2025, Deye reports cumulative inverter shipments of more than 5 million units, including 2 million hybrid inverters.

Deye’s product page identifies this architecture as a 100kW–2.5MW C&I ESS solution with 100/125kW PCS, 200kW MPPT and 500kW STS.

Which models are included in this Deye C&I ESS solution?

The supplied product range covers four specific models: SUN-STS500L, SUN-MPPT-L01-EU-AM8, SUN-100K-PCS01HP3 and SUN-125K-PCS01HP3. These modules are specified as part of the BOS-B Pro-A3 C&I ESS architecture.

What is the difference between the 100kW and 125kW PCS options?

The SUN-100K-PCS01HP3 has a rated AC input/output active power of 100kW, while the SUN-125K-PCS01HP3 is rated at 125kW. Both support lithium-ion batteries with a 630–1000V battery voltage range, use self-adaptation to BMS for the lithium-ion charging strategy and have maximum efficiency of 98.5%.

What does the SUN-STS500L do?

The STS module manages the PCS grid-connected/off-grid modes. It provides three independent power paths for diesel generator, load and grid connections, with each path rated at 500kW. It also provides less than 10ms on-grid/off-grid switching.

How much PV can the SUN-MPPT-L01-EU-AM8 handle?

The MPPT module has a maximum PV access power of 200kW and maximum PV input power of 160kW. It provides eight MPP trackers, with maximum operating current of 40A per tracker and maximum input short-circuit current of 60A per tracker.

How large can the BOS-B Pro-A3 battery system be?

The BOS-B Pro-A3 battery module is specified at 16.08kWh, 51.2V nominal voltage and 314Ah capacity. Between five and 16 modules can be connected in series. At the maximum configuration, the system reaches 819.2V nominal voltage, 257.23kWh system energy and 231.51kWh usable energy.

Can the system be expanded for larger C&I applications?

Yes. The Deye C&I ESS solution is specified for scalability up to 2.5MW using 100kW or 125kW PCS units. One STS module can connect to five 100kW PCS modules or four 125kW PCS modules, and up to five STS modules can be connected in parallel.

Read more
Dimensions and Weights
SKUSUN-STS500L
Weight108 kg
Dimensions67.1 x 54.3 x 57.5 cm
Dimensions and Weights
SKUSUN-MPPT-L01-EU-AM8
Weight41.75 kg
Dimensions70 x 54.3 x 19.8 cm
Dimensions and Weights
SKUSUN-100K-PCS01HP3
Weight81.86 kg
Dimensions77.5 x 54.3 x 31 cm
Dimensions and Weights
SKUSUN-125K-PCS01HP3
Weight81.86 kg
Dimensions77.5 x 54.3 x 31 cm
Dimensions and Weights
SKUBOS-B-PDU-2
Weight32 kg
Dimensions78.86 x 51.6 x 16.72 cm
Dimensions and Weights
SKUBOS-B-Pack16-A3
Weight126 kg
Dimensions79.59 x 52.6 x 27.42 cm
Download Area

Datasheet

Download

User Manual

Download

Deye NSW Peak Demand Reduction Scheme PDRS Solutions

Download
Specification Of
SUN-STS500L
Specification Of
SUN-STS500L
STS ModuleSUN-STS500L
Grid/PCS Side Data
Rated AC Input/Output Active Power(kW)500
Rated AC Input/Output Current(A)758/725
Rated Input/Output Voltage(V)220/380, 230/400 (three phase)
Grid Connection Form3L/N/PE
Rated Input/Output Grid Frequency50Hz/60Hz
Load Side Data
Rated Output Active Power(kW)   500
Rated Output Current(A)758/725
Rated Output Voltage(V)220/380, 230/400 (three phase)
Grid Connection Form3L/N/PE
Rated Output Grid Frequency   50Hz/60Hz
GEN Side Data
Rated AC Input Active Power(kW)   500
Rated AC Input Current(A)758/725
Rated Input Voltage(V)220/380, 230/400 (three phase)
Grid Connection Form3L/N/PE
Rated Input Grid Frequency   50Hz/60Hz
General Data
Off grid switching time <10ms
Operating Temperature Range (°C)-25℃ to 60℃
Permissible Ambient Humidity0-95%
Permissible Altitude (m)4000m
Ingress Protection(IP) RatingIP20
Over Voltage categoryOVC III
Warranty10 years
Cabinet Size[W×H×D] (mm)543x575x671
Weight (kg)108
Type Of CoolingNatural Cooling
Safety EMC/StandardIEC/EN 61439-1/-2
Features
DC port/AC portOT terminal
Communication InterfaceCAN/RS485
STS ModuleSUN-STS500L
Grid/PCS Side Data
Rated AC Input/Output Active Power(kW)500
Rated AC Input/Output Current(A)758/725
More Details
Specification Of
SUN-MPPT-L01-EU-AM8
Specification Of
SUN-MPPT-L01-EU-AM8
MPPT ModuleSUN-MPPT-L01-EU-AM8
PV String Input Data
Max. PV access power(kW)200
Max. PV Input Power(kW)160
Max. PV Input Voltage (V)800
Start-up Voltage (V) 200
MPPT Voltage Range (V)180-750
Full Load MPPT Voltage Range(V)450-750
Rated PV Input Voltage (V)600
Max. Operating PV Input Current (A)40+40+40+40+40+40+40+40
Max. Input Short-Circuit Current (A)60+60+60+60+60+60+60+60
No. of MPP Trackers8
DC Output Data
DC Output Voltage Range ( V )630-1000
Max. DC Output Current ( A )200
Efficiency
Max. Efficiency>99%
MPPT Efficiency>99.9%
Equipment Protection
DC input reverse protection   YES
DC ARC protectionOptional
Anti-PID(Potential Induced Degradation)Optional
DC SwitchYES
Surge Protection Level TYPE II
General Data
Operating Temperature Range (℃)-40℃ to 60℃
Permissible Ambient Humidity0-95%
Permissible Altitude (m)4000m
Ingress Protection(IP) Rating   IP65
Over Voltage CategoryOVC II
Cabinet Size[W×H×D] (mm)543x198x700
Weight (kg)41.75
Warranty10 years
Type Of CoolingIntelligent air cooling
Safety EMC/StandardIEC/EN 62109-1
Features
DC port/AC port   OT terminal
DisplayLED
Communication InterfaceCAN/RS485
MPPT ModuleSUN-MPPT-L01-EU-AM8
PV String Input Data
Max. PV access power(kW)200
Max. PV Input Power(kW)160
More Details
Specification Of
SUN-100K-PCS01HP3
Specification Of
SUN-100K-PCS01HP3
PCS ModelSUN-100K-PCS01HP3
Battery Data
Battery TypeLithium-ion
Battery Voltage Range (V)630-1000
Max. Charging Current (A)175
Max. Discharging Current (A)175
Charging Strategy for Li-ion BatterySelf-adaption to BMS
Number of Battery Input1
DC Input Data
DC Input Voltage Range(V)630-1000
Max. DC Input Current(A)200
AC Input/Output Data
Rated AC Input/Output Active Power (kW)100
Max. AC Input/Output Apparent Power (kVA)110
Rated AC Input/Output Current (A)151.6/145
Max. AC Input/Output Current (A)166.7/159.5
Rated Input/Output Voltage/Range(V)220/380, 230/400 0.85Un-1.1Un
Grid Connection Form3L+N+PE
Rated Input/Output Grid Frequency/Range50Hz/45Hz-55Hz   60Hz/55Hz-65Hz
Power Factor Adjustment Range-1~1
Total Current Harmonic Distortion THDi<3% (of nominal power)
DC Injection Current<0.5% In
Efficiency
Max. Efficiency98.5%
Euro Efficiency97.8%
Equipment Protection
IntegratedAC Output Overcurrent Protection, AC Output Overvoltage Protection,
AC Output Short Circuit Protection, Thermal Protection, Anti – islanding Protection,
Insulation Impedance Detection,Residual Current Detection
Surge Protection LevelTYPE II(DC),TYPE II(AC)
Interface
LCD/LED displayLCD
Communication InterfaceWIFI, RS485, CAN, Meter
General Data
Operating Temperature Range(℃)-40℃to -60℃,>45℃ Derating
Permissible Ambient Humidity0-95%
Permissible Altitude4000m
Noise<75dB
Ingress Protection(IP) RatingIP 65(PCS Module)
Cabinet Size[W×H×D] (mm)543x310x775(Excluding connectors and brackets)
Weight (kg)81.86
Inverter TopologyNon-Isolated
Over Voltage CategoryOVC II(DC), OVC III(AC)
Type of CoolingIntelligent Air Cooling
Warranty5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter,
More Info Please Refer to Warranty Policy
Grid RegulationIEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99,VDE-AR-N 4105
Safety/EMC StandardIEC/EN 62477-1
PCS ModelSUN-100K-PCS01HP3
Battery Data
Battery TypeLithium-ion
Battery Voltage Range (V)630-1000
More Details
Specification Of
SUN-125K-PCS01HP3
Specification Of
SUN-125K-PCS01HP3
S ModelSUN-125K-PCS01HP3
Battery Data
Battery TypeLithium-ion
Battery Voltage Range (V)630-1000
Max. Charging Current (A)200
Max. Discharging Current (A)200
Charging Strategy for Li-ion BatterySelf-adaption to BMS
Number of Battery Input1
DC Input Data
DC Input Voltage Range(V)630-1000
Max. DC Input Current(A)200
AC Input/Output Data
Rated AC Input/Output Active Power (kW)125
Max. AC Input/Output Apparent Power (kVA)125
Rated AC Input/Output Current (A)189.4/181.2
Max. AC Input/Output Current (A)189.4/181.2
Rated Input/Output Voltage/Range(V)220/380, 230/400 0.85Un-1.1Un
Grid Connection Form3L+N+PE
Rated Input/Output Grid Frequency/Range50Hz/45Hz-55Hz   60Hz/55Hz-65Hz
Power Factor Adjustment Range-1~1
Total Current Harmonic Distortion THDi<3% (of nominal power)
DC Injection Current<0.5% In
Efficiency
Max. Efficiency98.5%
Euro Efficiency97.8%
Equipment Protection
IntegratedAC Output Overcurrent Protection, AC Output Overvoltage Protection,
AC Output Short Circuit Protection, Thermal Protection, Anti – islanding Protection,
Insulation Impedance Detection,Residual Current Detection
Surge Protection LevelTYPE II(DC),TYPE II(AC)
Interface
LCD/LED displayLCD
Communication InterfaceWIFI, RS485, CAN, Meter
General Data
Operating Temperature Range(℃)-40℃to -60℃,>45℃ Derating
Permissible Ambient Humidity0-95%
Permissible Altitude4000m
Noise<75dB
Ingress Protection(IP) RatingIP 65(PCS Module)
Cabinet Size[W×H×D] (mm)543x310x775(Excluding connectors and brackets)
Weight (kg)81.86
Inverter TopologyNon-Isolated
Over Voltage CategoryOVC II(DC), OVC III(AC)
Type of CoolingIntelligent Air Cooling
Warranty5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter,
More Info Please Refer to Warranty Policy
Grid RegulationIEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99,VDE-AR-N 4105
Safety/EMC StandardIEC/EN 62477-1
S ModelSUN-125K-PCS01HP3
Battery Data
Battery TypeLithium-ion
Battery Voltage Range (V)630-1000
More Details
Specification Of
BOS-B-PDU-2
Specification Of
BOS-B-PDU-2
SpecificationBOS-B-PDU-2
Operating Voltage200~1000Vdc
Nominal Charge/Discharge Current180A
Operating Temperature-20~60°C
Ingress ProtectionIP20
AC Input Rating220±10%VAC/2A
Details526×788.6×167.2 (W×D×H), 32kg
SpecificationBOS-B-PDU-2
Operating Voltage200~1000Vdc
Nominal Charge/Discharge Current180A
Operating Temperature-20~60°C
More Details
Specification Of
BOS-B-Pack16-A3
Specification Of
BOS-B-Pack16-A3
SpecificationBOS-B-Pack16-A3
Nominal Capacity314Ah
Nominal Energy16.08kWh
Nominal Voltage51.2Vdc
Max Charge/Discharge Current180A
Ingress ProtectionIP20
Operating Temperature (Charge)0~55°C
Operating Temperature (Discharge)-20~55°C
Storage Temperature0~35°C
Details526×795.9×274.2 (W×D×H), 126kg
SpecificationBOS-B-Pack16-A3
Nominal Capacity314Ah
Nominal Energy16.08kWh
Nominal Voltage51.2Vdc
Max Charge/Discharge Current180A
More Details

FAQs

Reviews

Reviews

There are no reviews yet.

Be the first to review “Deye C&I ESS Solution, 100kW-2.5MW, Three Phase, 8/10 MPPT”

Your email address will not be published. Required fields are marked *